Focus on the beauty of science and technology
Based on the photovoltaic industry, with optical, mechanical, electronic based on the combination of the three core technologies
>Products>Teaching Experiment Microscope>Fluorescence Microscope
Large stage with adjustment in either hand
In order to correct the shortcoming of horizon guide rail, new stage is designed with double-way linear driving mechanism. This change protects the stage from overload at the end of both rails, improves the rigidity and performance of the stage.
Modular frame, improve the system compatibility
RX50 with modularization design, separated cross arm and main body, improves the system compatibility of biological and fluorescence frame.
Highly sensitive coaxial coarse and fine adjustment
Coaxial adjustment adopts double-stage driving, with adjustable tension tightness and upper limit stop, coarse range is 25mm and fine precision is 1μm. Not only accurately focus but also precision measurement is available.
Viewing head with multi-splitting ratio
RX50 viewing head is designed of multiple options for splitting ratio. with wide beam imaging system, 26.5mm super wide filed of view is available.
Optical system |
Infinity color corrected optical system |
Viewing head |
Inverted image, 30° inclined gemel trinocular head, interpupillary distance: 50mm~76mm; splitting ratio R:T=100:0 or 20:80 or 0:100 |
Erect image, 30° inclined gemel trinocular head, interpupillary distance: 50mm~76mm; splitting ratio R: T=100:0 or 0:100 |
|
Eyepiece |
High eyepoint wide field plan eyepiece PL10X25mm, diopter adjustable |
High eyepoint wide field plan eyepiece PL10X25mm, with reticle, diopter adjustable | |
High eyepoint wide field plan eyepiece PL10X26.5mm, diopter adjustable | |
High eyepoint wide field plan eyepiece PL10X26.5mm, with reticle, diopter adjustable | |
Objective |
Plan semi-apochromatic fluorescence objectives (4X/10X/20X/40X/100X) |
Nosepiece (with DIC slot) |
Quintuple nosepiece |
Sextuple nosepiece | |
Septuple nosepiece |
|
Frame |
Biological frame (transmitted), low-position coaxial coarse and fine adjustment, coarse adjustment distance: 25mm; fine precision: 0.001mm. With coarse adjustment stop and tightness adjustment.Built-in 100-240V_AC50/60Hz wide voltage transformer, intensity adjustable by digital set and reset; built-in transmitted filters LBD/ND6/ND25) |
Fluorescence frame (transmitted), low-position coaxial coarse and fine adjustment, coarse adjustment distance: 25mm; fine precision: 0.001mm. With coarse adjustment stop and tightness adjustment.Built-in 100-240V_AC50/60Hz wide voltage transformer, intensity adjustable by digital set and reset; built-in transmitted filters LBD/ND6/ND25). |
|
Stage |
Double layers mechanical stage, size: 187mm X168mm; moving range: 80mm X55mm; precision: 0.1mm; two-way linear drive, tension adjustable |
Condenser |
Swing-out type achromatic condenser (N.A.0.9) |
Reflected fluorescence illuminator |
Sextuple reflected fluorescence illuminator with iris field diaphragm and aperture diaphragm, central adjustable; with filter slot and polarizing slot; with fluorescence filters (UV/B/G for option). |
100W mercury lamp house, filament center and focus adjustable; with reflected mirror, mirror center and focus adjustable. (75W xenon lamp house for option) |
|
Digital power controller, wide voltage 100-240VAC | |
Imported OSRAM 100W mercury lamp.( OSRAM 75W xenon lamp for option) |
|
lamp house |
12V/100W halogen lamp house for transmitted light, center pre-set, intensity adjustable |
Other accessories |
Camera adapter: 0.5X/0.65X/1X focusing C-mount |
Cooled CCD camera, SONY2/3′′ 1.4M ICX285AQ COLOR CCD |
|
Centering objective for fluorescence observation |
|
Professional software for fluorescence analysis |
|
High precision micrometer, scale value 0.01mm |
to:input you register email